1
Nov

Free latest version

Below we will discuss exactly how to do this with FreeBSD’s sesutil or the management tools for your HBA. Though a truism, it bears emphasizing that with a little planning, management and maintenance of storage systems can be made easier and safer. The total throughput possible from the connected disks is still limited by the number of lanes available, but this is likely the best approach in systems with more than a dozen disks.

StarDesk – Remote Desktop & Gaming

The timer values specified are in milliseconds, so this example will park the disk heads after 30 minutes of inactivity. If we wanted to allow the disk to still park its heads but at minimum frequency, setting the APM value to 7Fh (hdparm -B 127) seems to be the correct choice. Of the three disks that I decided need some attention, I have one Western Digital disk and two Seagate ones.
SATA disks plugged directly into the motherboard use an interface called AHCI which does not provide much in the way of advanced management features. For smaller numbers of drives, and for most home systems, the most common way the disks are attached is to the SATA controllers built into the motherboard. Non-Volatile Memory Express (NVMe) is a newer storage interface that is becoming very popular for flash storage devices. Just download the executable file on both devices and run it to open the tool. At a glance, changing idle3 and EPC settings seems to have done the job nicely; here is the same graph of head park rates per disk as before, but on a smaller timescale that makes individual head parks visible. Seagate provide a “Seachest” collection of tools for manipulating their drives, but rather more usefully to users of non-Windows operating systems like Linux they also offer an open-source openSeaChest.

Constant HDD noise -> how to stop it?

We can also see that the disk in Slot07 was recently swapped, and that Slot08 does not contain a disk and its locate LED is activated. SES provides a mechanism to query information from the enclosure, including temperature, fan speed, and status of power supplies. Many backplanes include support for SCSI Enclosure Services (SES).

Help & Info about AnyDesk for Windows

Unnamed devices can be specified by their specific SES device and element number. This greatly reduces the chance of getting it wrong when you (or the datacenter technician) physically pulls the disk. You can also reboot, and GEOM will pick up the multipath when it first tastes the disks during boot.
Other interfaces for remote storage include iSCSI, Fiber-Channel, Infiniband, RoCE, and others, but those specialized solutions are beyond the scope of this article. Serial Attached SCSI (SAS) is the most common interface for enterprise storage, first appearing in 2004. Serial ATA (SATA) is the familiar interface used for non-enterprise storage, and is an extension of the original ATA interface dating from the 1980s. In this article we will discuss some strategies and tools to make managing disk arrays on FreeBSD (and related platforms like TrueNAS Core) much easier. It may be what you want is to enable HDD standby, which will “spin down” the drives when not in use

Preventing excessive parking

Unfortunately, APM settings don’t persist between power cycles so if we wanted to change disk settings with APM they would need to be reapplied on every boot. Advanced power management levels80h and higher do not permit the device to spin down to save power. For example, a device may implement one power management method from 80h to A0h and a higherperformance, higher power consumption method from level A1h to FEh. To prevent parking more often that is useful (for a server, usually that choice would be “very rarely”), there are a couple ways to do it and which apply will depend on what the hard drive vendor’s firmware supports. With the SMART metrics captured by Prometheus, it’s fairly easy to write a query that will show how often a given disk is parking its heads. Since I use Prometheus to capture information on the server’s operation however, I can use that to monitor that my hard drives are doing well.

  • Unnamed devices can be specified by their specific SES device and element number.
  • Simply installing the apps and choosing a pool for k3s and docker creates a dataset and logs.
  • SES provides a mechanism to query information from the enclosure, including temperature, fan speed, and status of power supplies.
  • Remember, the key is to act quickly and use the right tools for your specific situation.
  • With the tools presented here, the reader is well armed to react to failed disks and ensure that the wrong disk isn’t accidentally pulled.
  • SAS disk reservations provide the ability to connect to the disk redundantly—or even across multiple machines—while ensuring it is only used by one of them at a time.
  • Its primary purpose is to grant bidirectional remote access between personal computers and mobile devices.

I moved my Scale server into the next room, laundry room, just so it’s out of sight. Replacing the drive is financially out of the question. I’m looking for a software solution, if possible, to make the HDD idling for most of the time when there is no load. Yeah, it’s not helping, thanks. Although it’s empty, so this is probably not the source of the constant HDD noise.
I agree to receive your newsletters and accept the data privacy statement. Ensure device health & easy replacements with these valuable tips. Discover strategies to manage disk arrays on reveryplay FreeBSD and related platforms/operating systems. Simply installing the apps and choosing a pool for k3s and docker creates a dataset and logs. Your pool gets writes from somewhere and ZFS is writing those to disk every 5 seconds.
FreeBSD’s sesutil is a tool to interface with the SES devices on your system. You should also configure smartd to monitor your disks and send you alerts, which may give you advanced notice when a drive is starting to fail. These special boards, called SAS Expanders, reduce the total cabling required to provide power and signal pathways to all connected disks.
For ZFS users, automating fault responses with tools like ZED (ZFS Event Daemon) can simplify disk replacement and minimize downtime. Configuring your system to notify you when a disk has errors, or when the filesystem reports a degraded device, will ensure your system gets prompt attention when something goes wrong. Experienced enterprise storage managers also keep extensive notes including the model number, SKU and/or URL for reordering, purchase order information, warranty end date, warranty URL, and any other useful information about each drive. While the operating system typically provides device aliases based on the disk’s serial number, WWN, or some other static identifier, this does not provide all of the information you might want.
Once you’ve done so, you must test delivery to your “real” inbox—you don’t want to learn that delivery isn’t working after your storage has already become unavailable! If you’d feel safer with a team of experts monitoring your storage, consider a ZFS Support Subscription. If you rely on manually checking on your storage periodically, you will regret it. Another important aspect of managing your storage system is configuring notifications. Klara recommends embedding these details directly into the ZFS vdev properties of each disk—a feature Klara created, which will become generally available in the upcoming OpenZFS 2.2 release. In these configurations, your system may or may not support features like individual “locate” and “fault” LEDs.
This will activate the fault LED for element 9 (Slot 08) on the first SES device. You can avoid any uncertainty by enabling the “locate” or “fault” LED for the drive you mean to replace. This example creates a new GPT partition scheme on da36, creates a 4 GiB swap partition aligned to 1 MiB boundaries, and then adds a ZFS partition with the label e3s01-ZGY0XH87 using the remainder of the space on the disk.

  • NVMe on the other hand, supports multiple queues (often 64 queues, but the official specification allows for up to 65,536 queues) allowing for many commands to be run concurrently.
  • However, I noticed that my HDD’s heads park (particulary Seagate Exos) every 3 minutes.
  • The system is never idle really, it’s a server.
  • For quietness, a noise reducing case, move it somewhere else, quieter drives, maybe SSD instead of hard drives, etc.
  • It’s hard to imagine why your drives are that loud!

The APM specification dating from 1992 includes some controls for hard drives, allowing a host system to specify the desired performance level of a disk and whether standby is permitted by sending commands to a disk. In addition to the above query types, SES also supports a number of commands, including activating the “locate” and “fault” LEDs if present, and the ability to individually power off drives. The first step is to map out the relationship between the physical chassis where the disks reside, and the logical devices enumerated by the operating system.
Using the no-op true command on other paths to that disk, will cause GEOM to re-”taste” the disk and see the label and automatically add the additional paths to the existing multipath. This will write a GEOM Multipath label to the last sector of the disk. Each SAS Expander will present as a new /dev/ses# device, so your system may have more than one.
Sounds like the drives being woken for the ZIL to flush writes to the ZFS pool and then going back to idle/sleep every 5 seconds. Enable the checkmark for the Syslog and choose a pool that is not based on hard drives. I had this same problem, using HGST data center refurb drives.